FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Fuse protection function.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● hFE and db measurement.● With stand...makes reading and measuring easy. SPECIFICATIONS DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC. dB -10 to ± 50dB hFE 0-1000 ICEO 150uA, 15mA, 150mA LV 3V Dimensions 102(L) × 148(W) × 46(D)mm Weight (battery included) Approx. 300g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard IEC 1010-1 CAT II 1000V
FEATURES ● Lightweight, compact, and easy to use.● 4000 counts.● Full automatic measurement, voltage measurement, resistor measurement.● Data hold function.● Auto off function.● Continuity check.● Diode measurement.● Low battery indication.● Pen light provided.● Backlight LCD.● 3V DC power supply. SPECIFICATIONS DC Voltage Ranges 4V 40V 400V 600V Resolution 1mV 10mV 100mV 1V Accuracy ±(1%rdg+3dgt) ․Input impedance : 10MΩ AC Voltage Ranges 4V 40V 400V 600V Resolution 1mV 10mV 100mV 1V Accuracy ±(1.5%rdg+5dgt) ․Input impedance : 10MΩ Resistance Ranges 400Ω 4kΩ 40kΩ 400kΩ 4MΩ 40MΩ ...
FEATURES ● 4000 counts LCD with a maximum display of 3999.● Angled display design helps the user to identify the reading of value easier.● Auto ranging designed.● Bar graph LCD display.● Range change function.● Relative/Maximum/Minimum modes.● Peak hold mode.● VAHz mode measures frequency in voltage or current mode.● 40M Hz frequency counter.● Auto Power off.● Continuity check.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use. SPECIFICATIONS DC Voltage Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(0.5%rdg+3dgt) 1000V DC 4.000V 1mV 40.00V 10mV 400.0V 100mV 1000V 1V ․Input impedance : 10MΩ AC Voltage Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(1%rdg+5dgt) 800V...
FEATURES ● 3000 counts with a maximum display of 2999.● Angled display design helps the user to identify the reading of value easier.● Auto scanning function for AC/DC voltage, and current.● Auto ranging.● Range change function.● Continuity check.● Diode & Capacitance measurement.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use. SPECIFICATIONS DC Voltage Ranges Resolution Accuracy Input protection 300.0mV 100μV ±(0.5%rdg+3dgt) 1000V DC 3.000V 1mV 30.00V 10mV 300.0V 100mV 1000V 1V ․Input impedance : 10MΩ AC Voltage Ranges Resolution Accuracy Input protection 300.0mV 100μV ±(1%rdg+5dgt) 800V...
FEATURES ● 4000 counts LCD with a maximum display of 3999.● Angled display design helps the user to identify the reading of value easier.● Auto ranging designed.● Range change function.● Continuity check.● Diode measurement.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use. SPECIFICATIONS DC Voltage Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(0.5%rdg+3dgt) 1000V DC 4.000V 1mV 40.00V 10mV 400.0V 100mV 1000V 1V ․Input impedance : 10MΩ AC Voltage Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(1%rdg+5dgt) 800V AC 4.000V 1mV 40.00V 10mV 400.0V 100mV 750V 1V ․Input impedance : 10MΩ DC...
FEATURES ● 3½ digit, high contrast LCD, with a maximum display of 1999.● Automatic polarity indication, zero adjust.● Low battery (BAT) indication.● Over range indication: highest digit of (1) or (-1). ANALOG DISPLAY ● Large 90º wide and 84mm long mirror scale. (adapted to digital, analog maximum indication 2400).● Peak hold mode.● Shock and vibration resistant TAUT BAND movement.● Switch selection normal (left hand side) zero or center (galvo-mode) zero. Polarity + or -, pointer turn to right hand side, avoid opposite direction.● Centre zero and ohm zero : automatic● Dimensions: 167(L) × 102(W) × 39(D)mm SPECIFICATIONS DC...
FEATURES ● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case. SPECIFICATIONS Measuring ranges 0-200.0mΩ in steps of 100μΩ 0-2000mΩ in steps of 1mΩ 0-20.00Ω in steps of 10mΩ 0-200.0Ω in steps of 100mΩ 0-2000Ω in steps of 1Ω Accuracy ±0.5% of reading ±2 digits over the operating temperature range, -15ºC to +55ºC, with the supplied test leads Test current 1mA=>2000Ω range 10mA=>200 / 20Ω ranges 100mA=>2000m / 200mΩ ranges Test current accuracy ±0.1% Protection fuses Mains = 0.5A,...
FEATURES ● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case. SPECIFICATIONS Measuring ranges 0-200.0mΩ in steps of 100μΩ 0-2000mΩ in steps of 1mΩ 0-20.00Ω in steps of 10mΩ 0-200.0Ω in steps of 100mΩ 0-2000Ω in steps of 1Ω Accuracy ±0.5% of reading ±2 digits over the operating temperature range, -15ºC to +55ºC, with the supplied test leads Test current 1mA=>2000Ω range 10mA=>200 / 20Ω ranges 100mA=>2000m / 200mΩ ranges Test current accuracy ±0.1% Protection fuses Mains = 0.5A,...