FEATURES ● 2000 - count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ Capacitor measurement ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals. SPECIFICATIONS AC A 200.0/2000A (40~500Hz) 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 200.0mV ±(2.0%rdg+3dgt) 2.000/20.00/200.0/750V ±(1.5%rdg+3dgt) 40~500Hz DC A 200.0/2000A...
FEATURES ● 4000 - count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ Capacitor measurement ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals. SPECIFICATIONS AC A 400.0/2000A (40~500Hz) 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 400.0mV ±(2.0%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.5%rdg+3dgt) 40~500Hz DC A 400.0/2000A 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) DC V 400.0mV/4.000/40.00/400.0/1000V...
FEATURES ● Designed for testing AC current and AC voltage. ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication. SPECIFICATIONS AC Current Ranges Accuracy 50/60Hz WIDE 200mA(0~199.9mA) ±(1.5%rdg+2dgt) 40/1000Hz : ±(3.0%rdg+2dgt) 2A (0~1.999A) 20A(0~19.99A) 200A(0~199.9A) ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 0-500A ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 501-1000A ±5.5%rdg 40/1000Hz : ±10%rdg AC Voltage Ranges AC 200V/AC600V Resolution 0.1V / 1V Accuracy ±(1.5%rdg+3dgt) GENERAL Conductor size 55mm Max. Operating principle Dual slope integration Display 3½ digit (2000 counts) Low battery indication “ “ sign appears on the display when the battery voltage drops below accurate operating level ...
FEATURES ● Designed for testing AC current and AC voltage. ● 5 ranges for AC current testing. ● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication. SPECIFICATIONS AC Current Ranges Accuracy 50/60Hz WIDE 200mA(0~199.9mA) ±(1.5%rdg+2dgt) 40/1000Hz : ±(3.0%rdg+2dgt) 2A (0~1.999A) 20A(0~19.99A) 200A(0~199.9A) ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 0-500A ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 501-1000A ±5.5%rdg 40/1000Hz : ±10%rdg AC Voltage Ranges AC600V / DC600V Resolution 1V /1V Accuracy ±(1.5%rdg+3dgt)/ ±(1.0%rdg+2dgt) GENERAL Conductor size 55mm Max. Operating principle Dual slope integration Display 3½ digit (2000 counts) Low battery indication “ “ sign appears on the display when the battery voltage drops below accurate...
FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Fuse protection function.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● hFE and db measurement.● With stand...makes reading and measuring easy. SPECIFICATIONS DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC. dB -10 to ± 50dB hFE 0-1000 ICEO 150uA, 15mA, 150mA LV 3V Dimensions 102(L) × 148(W) × 46(D)mm Weight (battery included) Approx. 300g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard IEC 1010-1 CAT II 1000V
FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and db measurement.● With stand...makes reading and measuring easy.● Packaging...packed completely with AL-21 test leads, hFE leads, fuse, instruction manual. SPECIFICATIONS DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC dB -10 to ± 50dB hFE 0-1000 ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V Dimensions 100(L) × 150(W) × 41(D)mm Weight (battery included) Approx. 300g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard IEC 1010-1 CAT II 1000V
FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and db measurement.● With stand...makes reading and measuring easy. SPECIFICATIONS DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC dB -10dB~+22dB(for 10VAC)~+62dB hFE 0-1000 ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V Dimensions 100(L) × 150(W) × 41(D)mm Weight (battery included) Approx. 300g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard EN61010-1 CAT II 1000V EN61010-2-030 EN61326-1
FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and dB measurement.● LCD check function.● Battery test function.● Continuity test function.● With stand...makes reading and measuring easy. SPECIFICATIONS DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 9kΩ/V AC dB -10dB~+22dB hFE 0-1000 LED check ˇ Battery check GOOD or BAD ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V~0V Dimensions 100(L) × 150(W) × 41(D) mm Weight (battery included) Approx. 340g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard EN61010-1 CAT II 1000V...

