FEATURES ● Indicates phase rotation.        ● Indicates phase presence.● No battery required.● Phase rotation phase presence indicated on large    liquid crystal display.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 40Vac to   as high as 500Vac.● Fused.● Lightweight, robust and compact.● EN 61010-1 CAT III 500V   EN 61010-2-032     SPECIFICATIONS       ELECTRICAL     Determination of the Phase Presence Nominal Voltage for Phase Presence Indication (the voltage required for the LCD L1, L2, L3 indicators to come on) From 40Vac to 500Vac. Frequency range From 15Hz to 400Hz. Determination of the Phases Rotary Field Direction:   Direction Indication by LCD Display(the voltage required to have the LCD Direction Arrows to indicates and the L1 L2 L3 or L3 L2 L1 indicators to show) From 40 to 500Vac. Frequency range From 15 Hz to 400Hz Protection     Over load 700V(between...

FEATURES ● Indicates phase rotation.        ● Indicates phase presence.● Indicates motor rotation/wiring.● Indicates battery status.● Phase rotation and motor rotation indication works from as low as 1Vac.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 100 Vac. ● Very low consumption.● Fused.      ● Lightweight, robust and compact.● Works from 2 Hz to 400 Hz Sine.     SPECIFICATIONS       Phase Presence Nominal Voltage for Phase Presence Indication (The voltage required for the neon Lamps L1, L2, L3 to light up). From To Freq 100Vac 500Vac 10-400Hz Determination of Phase Rotation Field Direction From To Freq 1Vac 500Vac 2-400Hz Determination of Motor Connections (requires > 1/2 turn of the shaft) From To Freq 1Vac 500Vac 2-400Hz Maximum Current Consumption 18mA Over Voltage CLASS III 500V Over Load between all terminals 500V Battery OK goes off when battery voltage < 6.5 Vdc Dimensions ...

FEATURES ● The 4156 PR is used to identify the leads of a diconnected motor so    that when the motor is in true phase sequence, it will run in the    desired direction.     SPECIFICATIONS       Measuring ranges 0~200kΩ Test leads AL-34 length : 50cm Dimensions 250(L) × 190(W) × 110(D)mm Weight (battery included) Approx. 1280g Power source 1.5V (AA) × 2 Safety standard EN 61010-1 EN 61326-1

FEATURES ● Safely operates at low voltage       ● Measures system voltage.● Measures capacitance of test point if system voltage is known.● Checks phase rotation of cables.● Phases out cables.● Rugged - comes with portable case.● Operates from potential test point of elbow connec-tors.● Battery operated.      SPECIFICATIONS       Voltage ranges 0~16kV / 0~32kV Accuracy ±8% (exclusive of tap capacitance variations) Tap capacitance setting 0.4 to 3.0 pF continuous per channel Frequency 50 or 60 Hz Dimensions 250(L) × 190(W) × 110(D)mm Weight (battery included) Approx. 1420g Power source 1.5V (AA) × 4 Safety standard EN 61326-1

FEATURES ● Designed for measuring AC current, AC voltage resistance and DC   voltage .● Rotary scale which presents only one scale in windows at one time   to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach   places.● Ω range ideal for checking the continuity or relays, transformers and   motor coils.     SPECIFICATIONS         AC A 6 / 15 / 60 / 150 / 300A ±3% of F.S.(50/60Hz) AC V 300 / 600V ±3% of F.S. DC V 75V ±3% of F.S.   Ω 2kΩ ±3% of Scale length Frequency response 50 / 60Hz for ACA 6A 50-400Hz for ACA 15 / 60 / 150 / 300A Dimensions 230(L) × 72(W) × 37(D)mm Conductor size 38mm Max. Weight (battery Included) Approx. 420g Safety standard EN 61010-1 CAT II 600V EN 61010-2-32

FEATURES ● Rotary scale which presents only one scale in windows at one time   to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach   places.● Ω range ideal for checking the continuity or relays, transformers and   motor coils.     SPECIFICATIONS         AC A 6 / 30 / 60 / 300 / 600A ±3% of F.S.(50/60Hz) AC V 150 / 300 / 600V ±3% of F.S. DC V   ──   Ω 2kΩ ±3% of Scale length Frequency response 50 / 60Hz for ACA 6A 50-400Hz for ACA 30 / 60 / 300 / 600A Dimensions 230(L) × 72(W) × 37(D)mm Conductor size 38mm Max. Weight (battery Included) Approx. 420g Safety standard EN 61010-1 CAT II 600V EN 61010-2-32

FEATURES ● Rotary scale which presents only one scale in windows at one time   to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach   places.● Ω range ideal for checking the continuity or relays, transformers and   motor coils.● TAUT BAND movement.     SPECIFICATIONS             AC A 10 / 30 / 100 / 300 / 1000A ±3% of F.S.(50/60Hz) AC V 150 / 300 / 750V ±3% of F.S. DC V   ──   Ω 2kΩ ±3% of Scale length Frequency response 50 / 60Hz for ACA 10A 50-400Hz for ACA 30 / 100 / 300 / 1000A Dimensions 227(L) × 73(W) × 33(D)mm Conductor size 52mm Max. Weight (battery Included) Approx. 460g

FEATURES ● Full auto range for V.A and Ω functions.              ● Data hold function freezes the reading in dimly lit or    hard to reach places.        ● Low battery indication.        ● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal     parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays    transformers and motor coils.     SPECIFICATIONS         AC A 400A ±(2.0%rdg+3dgt) : 50/60Hz AC V 400 / 600V ±(1.2%rdg+3dgt) : 40-500Hz   Ω 4kΩ ±(1.5%rdg+3dgt) Buzzer sounds < 100Ω Conductor size 27mm Max. Low battery Indication   Dimensions 197(L) × 65(W) × 33(D)mm Weight (battery Included) Approx. 250g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT II 600V EN 61010-2-32