Products
FEATURES ● 3½ digit LCD with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges SPECIFICATIONS AC A 200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz) AC V 00 / 750V ±(1.5%rdg+2dgt) (40Hz-1kHz) DC A 200 / 1500A ±(2%rdg+4dgt) DC V 20 / 200 / 1000V ±(1%rdg+2dgt) Ω 200 / 1500Ω ±(1.5%rdg+2dgt) Diode check 0-1500mV ±(1.5%rdg+2dgt) Buzzer ── Conductor size 55mm Max. Operating temperature 0ºC ~ 40ºC Humidity 85% R.H. Current consumption Approx. 10mA Dimensions 245(L) × 70(W) × 41.7(D)mm Weight (battery Included) Approx. 480g Power source 9V(6F22) × 1
FEATURES ● 4000 counts.● Voltage measurement, current measurement, resistor measurement, frequency counter, capacitor measurement.● Bargraph indication.● Range change function.● Data hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Diode measurement.● Max / Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals. SPECIFICATIONS DC Voltage Ranges Resolution Accuracy 400mV 0.1mV ±(1.0%rdg+3dgt) 4V 1mV 40V 10mV 400V 100mV 600V 1V ․Overload protection : 650V DC AC Voltage Ranges Resolution Accuracy 400mV 0.1mV ±(0.5%rdg+3dgt) 4V 1mV ±(1.5%rdg+3dgt) 40V 10mV 400V ...
FEATURES ● Designed for testing AC current and AC voltage. ● 5 ranges for AC current testing. ● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication. SPECIFICATIONS AC Current Ranges Accuracy 50/60Hz WIDE 200mA(0~199.9mA) ±(1.5%rdg+2dgt) 40/1000Hz : ±(3.0%rdg+2dgt) 2A (0~1.999A) 20A(0~19.99A) 200A(0~199.9A) ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 0-500A ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 501-1000A ±5.5%rdg 40/1000Hz : ±10%rdg AC Voltage Ranges AC600V / DC600V Resolution 1V /1V Accuracy ±(1.5%rdg+3dgt)/ ±(1.0%rdg+2dgt) GENERAL Conductor size 55mm Max. Operating principle Dual slope integration Display 3½ digit (2000 counts) Low battery indication “ “ sign appears on the display when the battery voltage drops below accurate...
FEATURES ● Designed for testing AC current and AC voltage. ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication. SPECIFICATIONS AC Current Ranges Accuracy 50/60Hz WIDE 200mA(0~199.9mA) ±(1.5%rdg+2dgt) 40/1000Hz : ±(3.0%rdg+2dgt) 2A (0~1.999A) 20A(0~19.99A) 200A(0~199.9A) ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 0-500A ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 501-1000A ±5.5%rdg 40/1000Hz : ±10%rdg AC Voltage Ranges AC 200V/AC600V Resolution 0.1V / 1V Accuracy ±(1.5%rdg+3dgt) GENERAL Conductor size 55mm Max. Operating principle Dual slope integration Display 3½ digit (2000 counts) Low battery indication “ “ sign appears on the display when the battery voltage drops below accurate operating level ...
FEATURES ● High quality Taut Band movement.● Easy to read 3-color scale for mistake proof reading.● Mirror scale: makes reading pointer easy.● Safety features on all ranges.● Safety features: safety fused and safety “OFF” position.● dB measurement.● Built-in stand makes reading and measuring easy. SPECIFICATIONS DC Voltage Ranges 0.25 / 1 / 2.5 / 10 / 50 / 250 / 1000V Accuracy ±2% of full scale Sensitivity 50kΩ / V AC Voltage Ranges 2.5 / 10 / 50 / 250 / 1000V Accuracy ±3% of full scale Sensitivity 10kΩ / V Decibelmeter -20 to 62dB 0dB=1mW / 600Ω Direct Scale:-20 to +10dB DC Current Ranges 25uA/1mA/25mA/500mA, 10A(on separate input) Accuracy ±2% of full scale Sensitivity 250mV AC Current Ranges 10A Accuracy ±3% of full scale Resistance Ranges R × 1 0.2 to 20kΩ R ×...
FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and dB measurement.● LCD check function.● Battery test function.● Continuity test function.● With stand...makes reading and measuring easy. SPECIFICATIONS DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 9kΩ/V AC dB -10dB~+22dB hFE 0-1000 LED check ˇ Battery check GOOD or BAD ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V~0V Dimensions 100(L) × 150(W) × 41(D) mm Weight (battery included) Approx. 340g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard EN61010-1 CAT II 1000V...
FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and db measurement.● With stand...makes reading and measuring easy. SPECIFICATIONS DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC dB -10dB~+22dB(for 10VAC)~+62dB hFE 0-1000 ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V Dimensions 100(L) × 150(W) × 41(D)mm Weight (battery included) Approx. 300g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard EN61010-1 CAT II 1000V EN61010-2-030 EN61326-1
FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and db measurement.● With stand...makes reading and measuring easy.● Packaging...packed completely with AL-21 test leads, hFE leads, fuse, instruction manual. SPECIFICATIONS DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC dB -10 to ± 50dB hFE 0-1000 ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V Dimensions 100(L) × 150(W) × 41(D)mm Weight (battery included) Approx. 300g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard IEC 1010-1 CAT II 1000V

