OSCILLOSCOPES

Oscilloscopes, also called Digital Storage Oscilloscopes (DSOs) or Mixed Signal Oscilloscopes (MSOs), are a common type of test instrument used to capture, analyze, and troubleshoot electrical or real world physical signals. Oscilloscopes observe the change of electrical signals over time, continuously graphed on a display as voltage or amplitude vs. time. During observation, oscilloscopes can analyze waveforms parametrically (i.e. frequency, RMS, peak-to-peak amplitude, rise time, etc.) Non-electrical signals, especially mechatronic signals such as vibration, strain, temperature, or current can be converted to voltages and displayed.


Yokogawa oscilloscopes deliver a range of bandwidths, the world's only eight channel and sixteen channel (plus logic) oscilloscopes, unparalleled suites of triggers and signal analysis, and a unique ability to save multiple triggered-events to "History" memory.

  • Filter

Differential Probe, 12Vp Differential, 30Vp Common-Mode, 500MHz, 10:1, 100kΩ w/ built-in LEMO lead pig-tail Works with all scopes with BNC Input w/ 50Ω Input Termination. Requires 50Ω scope or use 700976 50Ω terminator. Requires /P2/P4 LEMO option or external probe power supply.

Frequency bandwidth: DC to 15 MHz Maximum continuous input range: 1000 Volts Attentuation Rations: 100:1 or 10:1 Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments.

Frequency bandwidth: DC to 50 MHz Maximum continuous voltage input: 7,000 Volts Attenuation ratios: 1000:1 or 100:1 Functions with Digital Oscilloscopes, ScopeCorders or other waveform measuring instruments.

Frequency bandwidth:  DC to 100 MHz Maximum continuous input range:  1400 Volts Attenuation Ratios:  100:1 or 1000:1   Functions with Digital Oscilloscopes, ScopeCorders or other waveform measuring instruments.

The 701927 is a 50:1 or 500:1 high voltage (1400V peak) probe with extended bandwidth covering DC to 150MHz, This probe provides a balanced differential input, to be used with oscilloscopes with single-ended inputs (1 MΩ Input Impedance).  This probe works with DLM2000, DLM4000, DL6000, DLM6000, DL9000 and SB5000. This probe is conveniently powered by the Yokogawa Probe Interface I/F.

Frequency bandwidth:  DC to 50 MHz Maximum continuous input range: 30 Arms Functions with Digital Oscilloscopes, Scopecorders or other waveform measuring instruments.

Frequency bandwidth:  DC to 100 MHz Maximum continuous input range: 30 Arms Functions with Digital Oscilloscopes, Scopecorders or other waveform measuring instruments.

Frequency bandwidth:  DC to 2 MHz Maximum continuous input range: 500 Arms Functions with Digital Oscilloscopes, Scopecorders and other waveform measuring instruments.